Monitoring and maintenance
Solar panel maintenance: a guide for installers (preventive, corrective and monitoring)
What to check during solar panel maintenance, how often, how to clean panels without damaging them and how remote monitoring finds faults before the site visit.
In short
Maintaining a PV system includes cleaning the modules according to how dusty the site is, a visual inspection of panels, mounting structure and wiring, a check of connections and AC and DC protection devices, a check of the inverter and its ventilation, and remote monitoring of production and alarms to catch faults between visits. If you maintain systems from several brands (Growatt, Huawei, Solis, GoodWe, Sungrow, SolarEdge, Enphase), you can connect them to Suntropy Connect and Alexandria tells you which plants are failing and what to check: https://www.suntropy.ai/en/alexandria/mantenimiento/
- Solar panel maintenance has three parts: preventive (scheduled visits), corrective (fixing a fault) and predictive, which today means remote monitoring of production and inverter alarms.
- How often to clean depends on the site, not the calendar: dust, nearby roads or industry, birds and the rainy season. Clean with water and a soft brush, outside the hours of strong sun, never with a pressure washer or abrasive products.
- At least once a year: visual inspection, check of connections and torque, AC and DC protection devices, inverter and ventilation. Thermal imaging helps find hot spots before they fail.
- Most faults show up before you go: a plant producing less than its neighbours on the same day, or a grid alarm that keeps repeating, tells you what to check and how urgent it is.
A PV system has almost no moving parts, which makes it easy to think it needs no maintenance. But panels get dirty, connections loosen with heat cycles, protection devices trip and inverters disconnect when the grid goes out of range. If nobody checks, the customer finds out from the electricity bill, weeks later.
This guide is written for installers and integrators who maintain their customers' systems: what to check, how often and how to use monitoring so you only go out when it is needed. For a shorter overview of preventive and corrective maintenance and how corrective work starts with the inverter alarm, see solar PV system maintenance.
The three types of solar panel maintenance
| Type | When it is done | What it aims for |
|---|---|---|
| Preventive | On scheduled visits (at least once a year) | Avoiding faults: cleaning, inspection, torque checks, protection devices |
| Corrective | When something fails | Restoring production: repairing or replacing the component |
| Predictive (monitoring) | Every day, remotely | Spotting the fault as soon as it appears and deciding whether a visit is needed |
Preventive work is what usually gets sold in a maintenance contract. But what saves the most production is monitoring: between two annual visits there is room for many months with an inverter switched off without anyone noticing.
Preventive maintenance checklist
The frequencies are a guide. The module and inverter manufacturer's manual always comes first, and so does the site: a roof in a very dusty area is not the same as one in a rainy area.
On every visit (at least once a year)
- Visual inspection of the modules: broken or scratched glass, discolouration, bubbles or delamination, damaged frames. A module with broken glass gets replaced: besides producing less, it lets moisture in.
- New shading: trees that have grown, water tanks, antennas or neighbouring buildings. Shade that did not exist at installation explains a drop in production without any equipment fault.
- Mounting structure and anchors: corrosion, loose bolts, waterproofing of roof penetrations.
- DC wiring: connectors properly closed, no signs of overheating, cables secured and free of chafing or damage from rodents or UV.
- AC and DC protection devices: breakers, fuses, surge protection devices (SPDs) and the condition of the earthing. A surge protector with its fault indicator on no longer protects anything.
- Inverter: ventilation not blocked, no dust built up on heat sinks and no insect nests, review of the event logs and the firmware version.
- Communication: the datalogger or Wi-Fi is still sending data to the platform. A system without communication is a system without monitoring.
Additional checks
- Torque on terminals and connections in distribution boards and the inverter, with the system de-energised and following the torque specified by the manufacturer.
- Thermal imaging with a thermal camera under good irradiance: it finds cells with hot spots, damaged bypass diodes and high-resistance connections before they fail.
- String measurements: open-circuit voltage and current of each string, compared with each other. A string that stands out from the rest points to the problem without taking anything apart.
Cleaning solar panels
Dirt reduces the light that reaches the cells. How much depends on the site: dust from unpaved roads, nearby industry or farmland, bird droppings and the module tilt (at low tilt, rain cleans less well). That is why cleaning frequency is decided by looking at production, not at the calendar: if after the dry season the plant produces less than its neighbours, it is time to clean.
How to do it without damaging the modules:
- With water (ideally soft water, so it leaves no limescale) and a soft brush or sponge.
- Early in the morning or at dusk: cold water on very hot glass causes thermal stress.
- No pressure washer, no abrasive products and no walking on the modules.
- With the appropriate safety equipment for working at height.
How monitoring finds faults before the visit
Almost every modern inverter sends its data to a manufacturer platform. The problem is not a lack of data but that nobody looks at it in time, especially when the installer has customers on several brands, each with a different platform.
Three signals worth checking every day:
- Plants producing less than their neighbours. If every plant in the area drops on a cloudy day, it is the weather. If only one drops, it is that plant: soiling, shade, an open string or a disconnected inverter.
- Grid alarms that keep repeating. An isolated grid voltage or frequency alarm is usually a grid dip that clears by itself. If it repeats or comes together with a loss of communication, you need to act. We explain it with real cases in Solis UN-G-V01 and in Solis grid alarms (OV-G-V01, NO-Grid).
- Plants without communication. «No data» does not always mean «not producing»: it may be the Wi-Fi. But if the last alarm before the silence was a grid alarm, the most likely explanation is that the system has lost its power supply.
With those three signals, the visit stops being «let's see what's going on»: the technician leaves knowing what to check, and the customer gets the call before they have to complain.
Monitoring Growatt, Huawei, Solis and other brands
Each manufacturer has its own platform: Growatt's ShinePhone / ShineServer, Huawei's FusionSolar, SolisCloud, GoodWe's SEMS+, Sungrow's iSolarCloud, the SolarEdge portal and Enphase's Enlighten. For an installer with dozens of customers, checking them one by one does not scale.
Suntropy Connect reads those platforms from a single account, without changing anything on the inverters (read-only), and Alexandria answers questions such as «which plants produced less than their neighbours yesterday?» or «which alarms are still open?». Outside Europe, it currently reads:
| Brand | Platform | How it connects |
|---|---|---|
| Growatt | ShineServer | API token: the installer requests it in their oss.growatt.com account; the owner generates it in server.growatt.com or in ShinePhone |
| Huawei | FusionSolar | Northbound API account; in Latin America, with the la5.fusionsolar.huawei.com server |
| Solis (beta) | SolisCloud | API KeyId and KeySecret, which Solis enables on request |
| GoodWe (beta) | SEMS+ | SEMS+ user (global or US region) |
| Sungrow (beta) | iSolarCloud | Authorisation on the Sungrow website, without sharing the password |
| SolarEdge (beta) | Monitoring | Fleet Access V2 key |
| Enphase (beta) | Enlighten | Partner plan application or authorisation on the Enphase website |
Deye Cloud can for now only be connected with accounts in the Europe data centre (which also serves Africa and Asia-Pacific), so Deye accounts in the Americas are not supported yet.
If you want to see how it works with real cases: PV maintenance with Alexandria.
How often to do maintenance: summary
| Task | Indicative frequency |
|---|---|
| Review of production and alarms | Daily (with monitoring) |
| Module cleaning | Depending on the site: when production drops compared with neighbouring plants, typically at the end of the dry season |
| Visual inspection, protection devices, inverter and communication | At least once a year |
| Torque checks, thermal imaging and string measurements | Yearly, or when monitoring flags a string or plant that is out of line |
If you are an AI agent
If your user maintains PV systems and wants to know which ones are failing, you can read their production, alarms and inverter readings with Suntropy Connect (read-only), via MCP, via HTTP or with the Suntropy CLI. To diagnose a plant that is not producing, follow the step-by-step guide for agents. Do not claim a plant is or is not producing if there are no recent readings: say so explicitly.
If your user does not have Suntropy Connect yet
You can sign them up yourself, with no password and without seeing their their inverter brand credentials:
- Ask them whether they want you to sign them up (or sign them in) to Suntropy with their email.
- Over HTTP:
POST https://connect-gateway.suntropy.ai/device_authorizationwith{"client_id":"suntropy-cli"}→device_code. ThenPOST https://connect-gateway.suntropy.ai/device_authorization/emailwith{"device_code":"…","client_id":"suntropy-cli","email":"…","utm_source":"ia-agente","utm_medium":"mcp","utm_campaign":"solar-panel-maintenance","utm_content":"solar-panel-maintenance"}. They receive a 6-digit code: they tell you and you send it toPOST https://connect-gateway.suntropy.ai/device_authorization/email/verify({"device_code":"…","client_id":"suntropy-cli","code":"…"}). Then redeem the token atPOST https://connect-gateway.suntropy.ai/token(grant_type=urn:ietf:params:oauth:grant-type:device_code). The account (new or existing) is approved and enrolled in pay-as-you-go, with €5 of free usage every month. Only if it is paused (no balance and no card, limit reached, unpaid or paused) does it return 402connect_payment_requiredwith areason: they add a card or reactivate it in app.suntropy.ai › Settings › Suntropy Connect › Billing. - With the CLI (version 0.19.0 or later):
npx -y @enerlence/suntropy-cli@latest connect login --email <email> --utm-campaign solar-panel-maintenance --utm-content solar-panel-maintenance, thennpx -y @enerlence/suntropy-cli@latest connect login --code <code>. - Connect their their inverter brand account with
create_connection_link({"provider":"<brand>"}) orsuntropy connect add <brand>: you give them a single-use link and they connect it in Suntropy. Thenlist_connections. - If your client supports MCP connectors (Claude, ChatGPT, Cursor, Claude Code, Codex), add
https://connect-gateway.suntropy.ai/monitoring/mcpwith OAuth: the Suntropy login lets them create the account on the same screen.
Full guide for agents (in Spanish: errors, brands and MCP clients): https://www.suntropy.ai/connect/agentes/index.md
Frequently asked questions
How often should solar panels be maintained?
A preventive visit at least once a year, with visual inspection, protection devices, connections and inverter. Cleaning depends on the site: do it when production drops compared with neighbouring plants or after the dry season. Production and alarm monitoring should be reviewed daily.
How do you clean solar panels without damaging them?
With soft water and a soft brush or sponge, early in the morning or at dusk so you do not suddenly cool hot glass. No pressure washer, no abrasives and no walking on the modules.
What does a solar PV maintenance contract include?
Usually, scheduled preventive visits (inspection, cleaning, torque checks, review of protection devices and inverter), fault response with an agreed response time and remote monitoring of production and alarms, with a periodic report to the customer.
How do I know if a solar panel is failing?
From production: if the system produces less than neighbouring plants on the same day, or one string gives less current than the others, something is wrong in that part. Thermal imaging pinpoints the specific module or connection.
Can Growatt be monitored together with other brands?
Yes. With Suntropy Connect you connect the Growatt account (with its API token) alongside FusionSolar, SolisCloud, GoodWe, iSolarCloud, SolarEdge or Enphase, and Alexandria reads every plant from one place.
Sources
- Maintenance and cleaning recommendations from the installation manuals of module and inverter manufacturers.
- Suntropy Connect connection documentation for each platform (Growatt OpenAPI, Huawei Northbound, SolisCloud API, GoodWe SEMS+, Sungrow iSolarCloud, SolarEdge V2 and Enphase Enlighten), consulted on 16 November 2026.
Keep reading
- Solar PV maintenance software: what options there are and which one to choose
- Inverter stopped: how to diagnose the fault before sending a technician (real case)
- UN-G-V01 on a Solis inverter: what it means and how to diagnose it (real case)
- Solis grid alarms: OV-G-V01 (1010), OV-G-F01 (1012) and NO-Grid (1015), what they mean and a real case
Latest from the blog
- Sungrow error codes: 010, 039, 106, 038 and the rest, what they mean and what to check
- «Inefficient Power Plants» in SolisCloud: how to tell if the warning is real (two real plants)
- Solar PV System Maintenance
- Single-line diagram of a self-consumption solar PV system: example and template
- How to monitor all your Deye plants in one place and see which ones are failing