Monitoring and maintenance

How to diagnose a solar inverter error with Claude (FusionSolar, SolarEdge, Solis, Growatt…)

How to get Claude (or ChatGPT) to diagnose an inverter alarm with the real data from FusionSolar, SolarEdge, SolisCloud, Growatt or Enphase: what it reads, in what order, which questions work and what it cannot do.

By Suntropy · Updated · Markdown

In short

Yes, if it reads the plant's real data. With Suntropy Connect (an official connector in Claude's directory, https://claude.ai/directory/connectors/suntropy-connect-monitoring) Claude reads the alarms, status and 5-minute readings from FusionSolar, SolarEdge, SolisCloud, Growatt, Enphase, Sungrow, GoodWe, Fronius, Deye and other brands, read-only, and tells you which alarm came first, what the readings show and what to check. Free account: https://app.suntropy.ai/signup

  • Claude can diagnose an inverter error with the plant's real data if it has a connector that reads the manufacturer's portal. That connector is Suntropy Connect, listed in Claude's official directory, reading 11 brands read-only.
  • The method is a technician's: portfolio overview → alarms in order → the inverter's 5-minute readings → diagnosis and what to ask the customer. The first alarm is usually the cause; the last one almost never is.
  • It works best with specific questions: the plant, the code and the time window. Eight ready-made prompts at the end.
  • Claude changes nothing on the inverter and cannot see what the platform does not record: a few-second voltage dip does not show in 5-minute readings. Remote diagnosis decides whether a visit is needed; it does not replace it.

When a plant turns red, a good technician always follows the same sequence: check what else is failing in the portfolio, read the alarms in order, open the inverter readings around the first one and only then decide. It is exactly the kind of work an assistant like Claude does well, as long as it can read the real data instead of guessing.

What Claude needs to diagnose with real data

Claude has no access to FusionSolar, SolarEdge or SolisCloud on its own. Without a connector it can only explain what a code means in general, often from another model's manual. To work with your plants it needs an MCP server that reads the manufacturers' portals.

Suntropy Connect Monitoring is that connector:

  • it is in Claude's official connector directory and also works with ChatGPT and with Alexandria, Suntropy's assistant;
  • it reads Huawei FusionSolar, SolarEdge, Enphase, SolisCloud, Growatt, Sungrow iSolarCloud, GoodWe SEMS, Fronius Solar.web, Deye Cloud, Riello and GreenHeiss;
  • it is read-only, and the manufacturer credentials are entered in Suntropy, never in the chat;
  • everything comes back normalised to kW and kWh, so different brands can be compared in one answer.

Setting it up takes about ten minutes: create the Suntropy account, connect each portal under Settings › Suntropy Connect › Connectors (or ask Claude for a connection link) and click Connect in Claude's directory. Per-brand requirements: connect SolarEdge, Enphase and other platforms to Claude.

The method, step by step (and the tool Claude uses at each one)

1. Look at the portfolio before the plant

First, context: is it only this plant, or several in the same area or of the same brand? Claude calls get_monitoring_summary, which returns per account the healthy, faulty and disconnected plants, the kWp and today's and this month's energy.

In a real portfolio of more than 200 plants across seven brands, that first answer separated one faulty plant from dozens of «disconnected» ones in seconds. Almost all the disconnected plants were old sites without communication for months, not today's incidents. Without that filter, the technician would have lost the morning.

2. Read the alarms in order, not the last one

Then list_alarms for the plant and a time window, oldest first. The most forgotten rule: the alarm that matters is usually the first. When a plant goes silent, the last alarm is almost always the communication one: the consequence, not the cause.

3. Confirm with the inverter readings

With the time of the first alarm, Claude asks for the inverter's 5-minute readings with get_device_history (one day per call) and, if needed, the live status with get_device_realtime. That is where you see what the alarm only suggests:

  • AC voltage at 0 V while the strings still show voltage: the site lost the grid;
  • high grid voltage at midday: overvoltage, as in Huawei alarm 2034;
  • one string at zero while the others are normal: connector, fuse or wiring of that string;
  • low insulation in the morning that clears as it dries: moisture, as in SolarEdge isolation errors.

4. The diagnosis and what to ask

With the three pieces, Claude proposes the most likely cause, what it cannot confirm remotely and two or three questions for the customer that decide whether the visit is urgent («did the RCD trip?», «was there roadwork in the street?», «did the power go out at home?»).

Prompts that work

The more specific the question, the better the diagnosis. Copy and adapt:

  • «Which plants have critical alarms open right now? Sort them by urgency.»
  • «My plant [name] has produced nothing since yesterday. Read me the alarms in order and tell me which came first.»
  • «Look at the inverter readings of [plant] between 10:00 and 14:00 yesterday: does the grid voltage drop, or a string?»
  • «Which Enphase systems have microinverters not reporting this week?»
  • «Which Huawei plants have been offline for more than a day, and what alarm did they have just before?»
  • «Compare today's production of [plant] with yesterday's at the same time.»
  • «Write a summary for the customer: what happened, what we checked and what we will do.»
  • «Tell me every morning about new alarms across all my plants.» (With Suntropy's alarm watching, which reads alarms every few minutes and keeps them with their state.)

What Claude cannot do

  • It does not touch the inverter. No restarts, no settings: the connector is read-only.
  • It does not see what the platform does not store. Readings arrive every 5 minutes; a voltage dip of a few seconds may not show. A normal last reading does not disprove the alarm.
  • It does not replace the visit when the problem is physical. It tells you when you need to go and what to bring.
  • It depends on the manufacturer's quota. Platforms ration their APIs, so ask about several plants in one question and do not repeat it.

Ask Claude

If your plants are in Suntropy Connect, Claude (or ChatGPT) runs this diagnosis on your real data: it reads the alarms in order, the inverter readings and the production, and tells you what to check. Copy this question:

My plant [name] shows alarm [code]. Read me the alarms of the last 7 days in order, look at the inverter readings around the first one and tell me the most likely cause, what to ask the customer and whether a visit is needed.

To connect it, open Suntropy Connect Monitoring in Claude's connector directory, click Connect and sign in with your Suntropy account (or create it on the same screen). It is read-only and every month includes €5 of free usage. How multi-brand monitoring works.

Frequently asked questions

Can I use it with ChatGPT?

Yes: the same connector is added in ChatGPT, and the prompts in this article work the same way.

What does it cost?

Suntropy Connect is pay-as-you-go: every month includes €5 of free usage, roughly seven plants monitored and analysed every week. After that, €0.50 to €0.25 per plant per month depending on the number of plants. No subscription, no lock-in and no card to start.

Does Claude see my FusionSolar or SolarEdge passwords?

No. Credentials are entered in Suntropy (or through a single-use link Claude gives you) and stored encrypted. Claude only receives the plant data.

Sources

Keep reading

Latest from the blog